MTP® Breakout Cables
Premium US Conec MTP® to LC Duplex Breakout Cables | 8-Fiber | OS2, OM3, OM4 | LSZH & Plenum
Professional-grade MTP® brand breakout cables with genuine US Conec connectors converting single MTP® connector to 4×LC duplex. Perfect for connecting premium MTP® trunk infrastructure to standard LC equipment. Available in Single Mode OS2, Multimode OM3, and OM4 with both LSZH and Plenum (OFNP) jacket options. Lengths from 1m to 30m.
Premium MTP® to LC Duplex Breakout Solutions
MTP® brand breakout cables represent the highest quality standard in MPO-to-LC connectivity, featuring genuine US Conec MTP® connectors on the MPO end and premium UPC-polished LC connectors on individual duplex legs. These cables provide the critical connection between high-density MTP® trunk infrastructure and standard LC equipment.
Our 8-fiber MTP® breakout cables feature one female MTP® connector on one end, fanning out to 4×LC duplex connectors on the other end. Each leg is color-coded following TIA-598 standards for easy identification. Available in both LSZH (Low Smoke Zero Halogen) for international installations and Plenum (OFNP) for North American air handling spaces.
Every MTP® breakout cable undergoes rigorous factory testing with comprehensive documentation. Premium components throughout: genuine US Conec MTP® connector, high-quality LC UPC connectors with ceramic ferrules, reinforced furcation point with strain relief, color-coded furcation tubing, and professional-grade LSZH or Plenum jacket meeting all fire safety codes.
Genuine US Conec MTP®
Color-Coded Legs
LSZH & Plenum Options
Why Choose MTP® Brand Breakout Cables
Genuine US Conec MTP® Brand
Premium brand MTP® connector with superior mechanical design, tighter tolerances, and removable housing. The gold standard for mission-critical deployments.
Premium MTP® to LC Conversion
Convert single MTP® trunk to 4 individual LC duplex connections. Perfect bridge between high-density MTP® infrastructure and standard LC equipment.
LSZH & Plenum Rated Options
Choose LSZH for international standards and environmental safety, or Plenum (OFNP) for North American air handling spaces. Both meet strict fire codes.
TIA-598 Color Coded Legs
Industry-standard color coding: Blue, Orange, Green, Brown. Quick visual identification prevents connection errors and simplifies documentation.
Enterprise-Grade Construction
Reinforced furcation point, strain relief boots on all connectors, flexible jacket rated for plenum or LSZH. Built to withstand data center environments.
Comprehensive Factory Testing
Every fiber pair tested for insertion loss and return loss. Detailed test reports with serial numbers for complete traceability and documentation.
Select Your Fiber Type & Jacket Rating
All MTP® breakout cables are 8-fiber configuration (MTP® Female to 4×LC UPC Duplex). Choose fiber type to match your application and jacket rating to meet your building codes. Genuine US Conec MTP® brand ensures premium quality across all options.
MTP® to 4×LC Duplex — 8F OS2 Single Mode LSZH
8-Fiber OS2 9/125μm Single-Mode | MTP® Female to 4×LC UPC Duplex | Yellow LSZH
Applications:
- ✓International data center deployments
- ✓Connect MTP® cassettes to 4 switches/servers
- ✓10GBASE-LR equipment connections
- ✓Campus backbone to equipment with LSZH
- ✓Long-reach breakout applications
Available Lengths — 8F OS2 LSZH Breakout
| Length | Part Number | Price | Ship Time | Action |
|---|---|---|---|---|
| 1 meter | MTP-OS2-8F-4LC-01M-LSZH | Request Quote | 2-3 days | Quote |
| 2 meters | MTP-OS2-8F-4LC-02M-LSZH | Request Quote | 2-3 days | Quote |
| 3 meters | MTP-OS2-8F-4LC-03M-LSZH | Request Quote | 2-3 days | Quote |
| 5 meters | MTP-OS2-8F-4LC-05M-LSZH | Request Quote | 2-3 days | Quote |
| 10 meters | MTP-OS2-8F-4LC-10M-LSZH | Request Quote | 2-5 days | Quote |
| 15 meters | MTP-OS2-8F-4LC-15M-LSZH | Request Quote | 3-5 days | Quote |
| 20 meters | MTP-OS2-8F-4LC-20M-LSZH | Request Quote | 3-5 days | Quote |
| 30 meters | MTP-OS2-8F-4LC-30M-LSZH | Request Quote | 3-5 days | Quote |
| Custom Length | Custom Part Number | Request Quote | 2-3 weeks | Quote |
MTP® to 4×LC Duplex — 8F OS2 Single Mode Plenum
8-Fiber OS2 9/125μm Single-Mode | MTP® Female to 4×LC UPC Duplex | Yellow Plenum (OFNP)
Applications:
- ✓Plenum-rated air handling spaces
- ✓Raised floor data center breakout
- ✓Drop ceiling installations
- ✓Long-reach equipment connections
- ✓North American code compliance
Available Lengths — 8F OS2 Plenum Breakout
| Length | Part Number | Price | Ship Time | Action |
|---|---|---|---|---|
| 1 meter | MTP-OS2-8F-4LC-01M-OFNP | Request Quote | 2-3 days | Quote |
| 2 meters | MTP-OS2-8F-4LC-02M-OFNP | Request Quote | 2-3 days | Quote |
| 3 meters | MTP-OS2-8F-4LC-03M-OFNP | Request Quote | 2-3 days | Quote |
| 5 meters | MTP-OS2-8F-4LC-05M-OFNP | Request Quote | 2-3 days | Quote |
| 10 meters | MTP-OS2-8F-4LC-10M-OFNP | Request Quote | 2-5 days | Quote |
| 15 meters | MTP-OS2-8F-4LC-15M-OFNP | Request Quote | 3-5 days | Quote |
| 20 meters | MTP-OS2-8F-4LC-20M-OFNP | Request Quote | 3-5 days | Quote |
| 30 meters | MTP-OS2-8F-4LC-30M-OFNP | Request Quote | 3-5 days | Quote |
| Custom Length | Custom Part Number | Request Quote | 2-3 weeks | Quote |
MTP® to 4×LC Duplex — 8F OM3 Multimode LSZH
8-Fiber OM3 50/125μm Multimode | MTP® Female to 4×LC UPC Duplex | Aqua LSZH
Applications:
- ✓International data center 10G breakout
- ✓Connect MTP® cassettes to 4 10G switches
- ✓40GBASE-SR4 to 4×10GBASE-SR breakout
- ✓Enterprise equipment with LSZH requirement
- ✓Cost-effective breakout solution
Available Lengths — 8F OM3 LSZH Breakout
| Length | Part Number | Price | Ship Time | Action |
|---|---|---|---|---|
| 1 meter | MTP-OM3-8F-4LC-01M-LSZH | Request Quote | 2-3 days | Quote |
| 2 meters | MTP-OM3-8F-4LC-02M-LSZH | Request Quote | 2-3 days | Quote |
| 3 meters | MTP-OM3-8F-4LC-03M-LSZH | Request Quote | 2-3 days | Quote |
| 5 meters | MTP-OM3-8F-4LC-05M-LSZH | Request Quote | 2-3 days | Quote |
| 10 meters | MTP-OM3-8F-4LC-10M-LSZH | Request Quote | 2-5 days | Quote |
| 15 meters | MTP-OM3-8F-4LC-15M-LSZH | Request Quote | 3-5 days | Quote |
| 20 meters | MTP-OM3-8F-4LC-20M-LSZH | Request Quote | 3-5 days | Quote |
| 30 meters | MTP-OM3-8F-4LC-30M-LSZH | Request Quote | 3-5 days | Quote |
| Custom Length | Custom Part Number | Request Quote | 2-3 weeks | Quote |
MTP® to 4×LC Duplex — 8F OM3 Multimode Plenum
8-Fiber OM3 50/125μm Multimode | MTP® Female to 4×LC UPC Duplex | Aqua Plenum (OFNP)
Applications:
- ✓Plenum-rated 10G breakout
- ✓Raised floor data centers
- ✓Drop ceiling installations
- ✓40G to 4×10G with plenum rating
- ✓Enterprise plenum deployments
Available Lengths — 8F OM3 Plenum Breakout
| Length | Part Number | Price | Ship Time | Action |
|---|---|---|---|---|
| 1 meter | MTP-OM3-8F-4LC-01M-OFNP | Request Quote | 2-3 days | Quote |
| 2 meters | MTP-OM3-8F-4LC-02M-OFNP | Request Quote | 2-3 days | Quote |
| 3 meters | MTP-OM3-8F-4LC-03M-OFNP | Request Quote | 2-3 days | Quote |
| 5 meters | MTP-OM3-8F-4LC-05M-OFNP | Request Quote | 2-3 days | Quote |
| 10 meters | MTP-OM3-8F-4LC-10M-OFNP | Request Quote | 2-5 days | Quote |
| 15 meters | MTP-OM3-8F-4LC-15M-OFNP | Request Quote | 3-5 days | Quote |
| 20 meters | MTP-OM3-8F-4LC-20M-OFNP | Request Quote | 3-5 days | Quote |
| 30 meters | MTP-OM3-8F-4LC-30M-OFNP | Request Quote | 3-5 days | Quote |
| Custom Length | Custom Part Number | Request Quote | 2-3 weeks | Quote |
MTP® to 4×LC Duplex — 8F OM4 Multimode LSZH ⭐
8-Fiber OM4 50/125μm Multimode | MTP® Female to 4×LC UPC Duplex | Magenta LSZH
Applications:
- ✓40G/100G MTP® infrastructure breakout
- ✓International data center deployments
- ✓Connect MTP® cassettes to 25G servers
- ✓Premium breakout solution with LSZH
- ✓Future-proof 10G/25G connections
⭐ Why OM4 LSZH is Recommended:
- Genuine US Conec MTP® brand
- Supports 10G/25G equipment
- LSZH for international standards
- Best choice for modern global deployments
Available Lengths — 8F OM4 LSZH Breakout
| Length | Part Number | Price | Ship Time | Action |
|---|---|---|---|---|
| 1 meter | MTP-OM4-8F-4LC-01M-LSZH | Request Quote | 2-3 days | Quote |
| 2 meters | MTP-OM4-8F-4LC-02M-LSZH | Request Quote | 2-3 days | Quote |
| 3 meters | MTP-OM4-8F-4LC-03M-LSZH | Request Quote | 2-3 days | Quote |
| 5 meters | MTP-OM4-8F-4LC-05M-LSZH | Request Quote | 2-3 days | Quote |
| 10 meters | MTP-OM4-8F-4LC-10M-LSZH | Request Quote | 2-5 days | Quote |
| 15 meters | MTP-OM4-8F-4LC-15M-LSZH | Request Quote | 3-5 days | Quote |
| 20 meters | MTP-OM4-8F-4LC-20M-LSZH | Request Quote | 3-5 days | Quote |
| 30 meters | MTP-OM4-8F-4LC-30M-LSZH | Request Quote | 3-5 days | Quote |
| Custom Length | Custom Part Number | Request Quote | 2-3 weeks | Quote |
MTP® to 4×LC Duplex — 8F OM4 Multimode Plenum ⭐
8-Fiber OM4 50/125μm Multimode | MTP® Female to 4×LC UPC Duplex | Magenta Plenum (OFNP)
Applications:
- ✓40G/100G plenum-rated breakout
- ✓Raised floor data centers
- ✓Drop ceiling installations
- ✓Connect MTP® cassettes to 25G servers in plenum spaces
- ✓Premium North American deployments
⭐ Why OM4 Plenum is Recommended:
- Genuine US Conec MTP® brand
- Required for US plenum/raised floor spaces
- Supports 10G/25G equipment
- Best choice for North American premium deployments
Available Lengths — 8F OM4 Plenum Breakout
| Length | Part Number | Price | Ship Time | Action |
|---|---|---|---|---|
| 1 meter | MTP-OM4-8F-4LC-01M-OFNP | Request Quote | 2-3 days | Quote |
| 2 meters | MTP-OM4-8F-4LC-02M-OFNP | Request Quote | 2-3 days | Quote |
| 3 meters | MTP-OM4-8F-4LC-03M-OFNP | Request Quote | 2-3 days | Quote |
| 5 meters | MTP-OM4-8F-4LC-05M-OFNP | Request Quote | 2-3 days | Quote |
| 10 meters | MTP-OM4-8F-4LC-10M-OFNP | Request Quote | 2-5 days | Quote |
| 15 meters | MTP-OM4-8F-4LC-15M-OFNP | Request Quote | 3-5 days | Quote |
| 20 meters | MTP-OM4-8F-4LC-20M-OFNP | Request Quote | 3-5 days | Quote |
| 30 meters | MTP-OM4-8F-4LC-30M-OFNP | Request Quote | 3-5 days | Quote |
| Custom Length | Custom Part Number | Request Quote | 2-3 weeks | Quote |
MTP® Breakout: LSZH vs Plenum Jacket Comparison
| Feature | LSZH Jacket | Plenum (OFNP) Jacket |
|---|---|---|
| Fire Safety | Low Smoke Zero Halogen | OFNP Fire Rated |
| Best For | International installations | North American air handling spaces |
| Standards | IEC 60754-1, IEC 61034 | UL 910, NFPA 262 |
| Typical Use | Global data centers, Europe, Asia | Raised floors, drop ceilings, plenum spaces |
| Environmental | Eco-friendly, no halogens | Fire-retardant materials |
| Cost | Standard pricing | Premium pricing |
Quick Jacket Selection Guide:
Request a quote
FREQUENTLY ASKED QUESTIONS
Have questions about MTP® breakout cables? We’ve compiled answers to the most common questions from our customers.
